Tagify TnX Universal Adapter-loaded Transposase

 

Tagify TnX Universal Adapter-Loaded Transposase is ideal for simplereliable, high-performance library preparation to support a variety of applications, such as ATAC-Seq and other NGS assays that rely on Illumina-compatible sequence adapters.

  • Rapid library prep: simultaneously fragment and tag DNA via loaded transposase
  • Ready-to-use: TnX pre-loaded with Illumina-compatible universal adapters
  • Uniform sequence coverage: next-generation TnX transposase with increased activity, enzyme robustness and reduced insertion bias
  • Trusted results: fully QC’d loaded transposase for batch-to-batch consistency

Tagify TnX P5

Adapter sequence:  5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3’ (33 bases)

Concentration:  0.2 units* / µL

 

Tagify TnX P7

Adapter sequence:  5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG-3’ (34 bases)

Concentration:  0.2 units* / µL

 

Mosaic End (ME) sequence underlined

*Unit definition: One unit is the amount of tagging reagent required to fragment 100 ng of E. coli genomic DNA to an average length of 650 – 850 bp in 5 minutes at 55°C in 1X Coding Buffer in a 50 µL total reaction volume.

seqWell TnX Next-Generation Transposase

TnX Next-Generation Transposase

seqWell used fit-for-purpose engineering to develop the next-generation transposase, called TnX, that is optimized for use in NGS library preparation.   Learn more about TnX by reading our blog entitled “Breaking the Transposase Bias”

Read Blog

Looking for a transposases loaded with a different payload?

Check out our Tagify Custom-loaded Transposase Reagents

Tagify TnX Universal Adapter Specifications

Specs Description
Primary Applications NGS assays requiring Illumina-compatible sequence adapters
Sample Types
  • Various forms of DNA
Kit Sizes (units*)
  • 50μL at 0.2 U/μL
  • 200μL at 0.2 U/μL
Transposase TnX
Barcoding Strategy
  • P5/Read 1 Illumina-compatible adapter
  • P7/Read 2 Illumina-compatible adapter
Average Output Fragment Range** (measured with Agilent DNA BioAnalyzer Chip) 650 – 850 bp
Sequencer Compatibility All Illumina sequencing platforms;
Use with Element Biosciences AVITI™ or other sequencing platforms is possible with conversion kits for Illumina libraries

*1 unit of Universal adapter-loaded TnX is defined as the amount of tagging reagent required to fragment 100 ng E. coli genomic DNA to an average length of 650-850 bp in 5 minutes at 55°C in 1X Coding Buffer in a 50 μL total reaction volume. The average fragment length is determined by electrophoresis on the Agilent TapeStation.

**Because the tagged product in not a complete NGS library, sizing data and traces obtained from other methods, such as Agilent TapeStation or Femto Pulse, may vary.

 

Tagify™ TnX Universal Adapter-loaded Transposase Resources

A Guide to Selecting the Right Gene Editing Off-Target Assay

Loading...